{"id":3874,"date":"2026-11-24T02:56:46","date_gmt":"2026-11-24T02:56:46","guid":{"rendered":"https:\/\/jimiactuators.com\/?p=3874"},"modified":"2026-11-24T03:00:50","modified_gmt":"2026-11-24T03:00:50","slug":"how-a-servo-motor-linear-actuator-solved-it","status":"publish","type":"post","link":"https:\/\/jimiactuators.com\/ko\/how-a-servo-motor-linear-actuator-solved-it\/","title":{"rendered":"Case Study: Why a Standard 12V Actuator Linear Solution Failed at 1600 N \/ 150 mm\/s \u2014 and How a Servo Motor Linear Actuator Solved It"},"content":{"rendered":"<h1 class=\"kme-h1\" dir=\"ltr\">Case Study: Why a Standard 12V Actuator Linear Solution Failed at 1600 N \/ 150 mm\/s \u2014 and How a Servo Motor Linear Actuator Solved It<\/h1>\n<p class=\"kme-paragraph\" dir=\"ltr\">When a customer&#8217;s specification lands on your desk with high force, high speed, and near-continuous duty in the same row, the first engineering instinct should be caution \u2014 not a catalog search. This case study walks through a real project in which a customer required <b><strong class=\"kme-text-bold\">1600 N of thrust at 150 mm\/s over a 100 mm stroke, at 80\u2013100% duty cycle, in a package weighing roughly 1.5 kg<\/strong><\/b>. Our PA2-series <a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/l\/\"><b><strong class=\"kme-text-bold\">electromechanical linear actuator<\/strong><\/b><\/a> matched the weight target almost perfectly, yet the analysis below shows exactly why it \u2014 and every comparable DC lead-screw actuator in its class \u2014 cannot meet this duty point, and why the correct answer is a <b><strong class=\"kme-text-bold\">servo motor linear actuator<\/strong><\/b>, specifically a ball-screw <b><strong class=\"kme-text-bold\">\uc804\uae30 \uc2e4\ub9b0\ub354<\/strong><\/b>.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/l\/\"><img decoding=\"async\" class=\"aligncenter size-fusion-800 wp-image-3875\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-800x446.png\" alt=\"\" width=\"800\" height=\"446\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-18x10.png 18w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-200x112.png 200w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-300x167.png 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-400x223.png 400w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-600x335.png 600w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-768x429.png 768w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2-800x446.png 800w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig1-requirement-vs-pa2.png 887w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2 class=\"kme-h2\" dir=\"ltr\">1. The Customer&#8217;s Application and Requirements<\/h2>\n<p class=\"kme-paragraph\" dir=\"ltr\">The customer is building an automated positioning mechanism for a production line. The actuator must push a tooling load repeatedly, cycle after cycle, for entire shifts with minimal downtime. The specification is summarized below:<\/p>\n<table class=\"kme-table\">\n<colgroup>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"kme-table-row\">\n<th class=\"kme-table-cell kme-table-cell-header\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ub9e4\uac1c\ubcc0\uc218<\/p>\n<\/th>\n<th class=\"kme-table-cell kme-table-cell-header\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Customer Requirement<\/p>\n<\/th>\n<th class=\"kme-table-cell kme-table-cell-header\">\n<p class=\"kme-paragraph\" dir=\"ltr\">PA2-Series Baseline (lead screw, 12V DC gearmotor)<\/p>\n<\/th>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Rated thrust<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">1600 N<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">1600 N (at low speed)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Rated speed<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">150 mm\/s<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">10\u201320 mm\/s at rated load<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ub1cc\uc878\uc911<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">100 mm<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">100 mm (available)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ub4c0\ud2f0 \uc0ac\uc774\ud074<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">80\u2013100% (continuous operation)<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">10\u201325% (typically 2 min ON \/ 18 min OFF)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Total weight<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\u2248 1.5 kg<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\u2248 1.4 kg<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Supply<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">DC, compact envelope<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">12 V DC brushed gearmotor<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"kme-paragraph\" dir=\"ltr\">At first glance the match looks tempting: thrust, stroke, and weight all align. That is precisely the trap. The two parameters that define this application \u2014 speed and duty cycle \u2014 are exactly the two parameters that a lead-screw <b><strong class=\"kme-text-bold\">12v actuator linear<\/strong><\/b> product is structurally incapable of delivering. The rest of this article quantifies why.<\/p>\n<p dir=\"ltr\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ed%8f%ac%ed%8a%b8%ed%8f%b4%eb%a6%ac%ec%98%a4-%ed%95%ad%eb%aa%a9\/pa2-%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0\/\"><img decoding=\"async\" class=\"aligncenter size-fusion-800 wp-image-2846\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-800x421.jpg\" alt=\"\" width=\"800\" height=\"421\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-200x105.jpg 200w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-300x158.jpg 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-400x211.jpg 400w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-600x316.jpg 600w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-768x404.jpg 768w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1-800x421.jpg 800w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2021\/10\/PA2-1.jpg 950w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2 class=\"kme-h2\" dir=\"ltr\">2. The Physics: 240 W of Continuous Mechanical Power<\/h2>\n<p class=\"kme-paragraph\" dir=\"ltr\">Start with the working point itself:<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">P = F \u00d7 v = 1600 N \u00d7 0.15 m\/s = 240 W of mechanical output power.<\/strong><\/b><\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\">240 W may not sound dramatic in an industrial context, but for a 1.5 kg self-contained actuator it is a severe demand. Everything that follows is a consequence of this one number and the efficiency of the drivetrain that must produce it.<\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">2.1 Screw efficiency turns 240 W into an 800 W problem<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\">A conventional ACME\/trapezoidal lead screw with a polymer or bronze nut \u2014 the heart of the PA2 series and of virtually every economy <b><strong class=\"kme-text-bold\">electromechanical linear actuator<\/strong><\/b> \u2014 converts rotary motion to linear motion at only <b><strong class=\"kme-text-bold\">25\u201340% efficiency<\/strong><\/b>, because it works by sliding friction. Taking 30% as a representative figure:<\/p>\n<ul class=\"kme-ul\">\n<li class=\"kme-listitem\" value=\"1\">Electrical input required: 240 W \u00f7 0.30 \u2248 <b><strong class=\"kme-text-bold\">800 W<\/strong><\/b><\/li>\n<li class=\"kme-listitem\" value=\"2\">Before even reaching the screw, the brushed DC gearmotor adds its own losses (60\u201370% efficiency), pushing real input demand toward <b><strong class=\"kme-text-bold\">1000\u20131200 W<\/strong><\/b><\/li>\n<li class=\"kme-listitem\" value=\"3\">At 12 V, that implies a continuous current of <b><strong class=\"kme-text-bold\">70\u2013100 A<\/strong><\/b><\/li>\n<\/ul>\n<p class=\"kme-paragraph\" dir=\"ltr\">No motor, gearbox, wiring, or thermal design can fit 70\u2013100 A of continuous current into a 1.5 kg package. For perspective, the entire PA2 actuator draws roughly 5\u201310 A at full load. The requirement is an order of magnitude beyond what the architecture can supply \u2014 this is not a tuning problem, it is a physics wall.<\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">2.2 The speed\u2013thrust trade-off is hard-wired by the gear ratio<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\">A lead-screw actuator&#8217;s output is locked to a single kinematic chain:<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">Linear speed = motor rpm \u00d7 screw lead \u00f7 gear ratio<\/strong><\/b><\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\">To get 1600 N of thrust from a small DC motor, the PA2 uses a high reduction ratio (often 20:1 to 40:1) and a fine screw lead. That same reduction divides the speed down to 10\u201320 mm\/s. To reach 150 mm\/s, you would need to cut the reduction by roughly 10\u00d7 \u2014 which would simultaneously cut available thrust by roughly 10\u00d7, to around 160 N. <b><strong class=\"kme-text-bold\">Thrust and speed are the same coin.<\/strong><\/b> No single-ratio lead-screw design can deliver 1600 N and 150 mm\/s from a 1.5 kg-class DC motor; the motor would need to spin the screw at several thousand rpm while sustaining full torque, far outside its continuous rating.<\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">2.3 Duty cycle: where the requirement becomes truly impossible<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\">Even if the speed problem were somehow solved, the <b><strong class=\"kme-text-bold\">80\u2013100% duty cycle<\/strong><\/b> requirement is the decisive knockout. Duty cycle for a DC gearmotor actuator is a thermal rating: it expresses how long the motor windings and screw nut can run before heat must dissipate. PA2-class actuators are rated at <b><strong class=\"kme-text-bold\">10\u201325% duty<\/strong><\/b> \u2014 for example, a maximum of 2 minutes ON within any 10-minute window \u2014 because:<\/p>\n<ol class=\"kme-ol\">\n<li class=\"kme-listitem\" value=\"1\"><b><strong class=\"kme-text-bold\">The brushed motor generates heat continuously<\/strong><\/b> (copper losses scale with the square of current), and the compact sealed housing has almost no thermal path to remove it.<\/li>\n<li class=\"kme-listitem\" value=\"2\"><b><strong class=\"kme-text-bold\">Sliding friction in the lead screw converts 60\u201370% of input power directly into heat at the nut interface<\/strong><\/b>, exactly where the polymer nut has the lowest temperature tolerance.<\/li>\n<li class=\"kme-listitem\" value=\"3\"><b><strong class=\"kme-text-bold\">Brushes and the plastic\/spur gearbox wear in proportion to running hours.<\/strong><\/b> At 100% duty, a mechanism designed for years of intermittent service accumulates a year&#8217;s worth of brush wear in weeks.<\/li>\n<\/ol>\n<p class=\"kme-paragraph\" dir=\"ltr\">Running a 20%-duty actuator at 80\u2013100% duty does not produce 80% performance \u2014 it produces thermal shutdown, accelerated brush failure, nut softening and backlash, and ultimately seizure. In a production-line application, that translates into unplanned downtime within the first weeks of operation.<\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">2.4 Life calculation confirms the verdict<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\">At 150 mm\/s and 100 mm stroke, each full extend\u2013retract cycle takes under 1.5 seconds of motion. At 80% duty over a single 8-hour shift, the actuator would complete on the order of <b><strong class=\"kme-text-bold\">15,000\u201320,000 cycles per day<\/strong><\/b>. Lead-screw actuators of this class carry typical L10 lives of tens of thousands of cycles at rated load; the customer would consume the entire design life in days. The duty-cycle and life requirements are really the same requirement: this application is a <i><em class=\"kme-text-italic\">continuous-motion machine<\/em><\/i>, and the PA2 is an <i><em class=\"kme-text-italic\">intermittent-positioning device<\/em><\/i>.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/%ec%a0%84%ea%b8%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/\"><img decoding=\"async\" class=\"aligncenter size-fusion-800 wp-image-3876\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-800x349.png\" alt=\"\" width=\"800\" height=\"349\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-18x8.png 18w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-200x87.png 200w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-300x131.png 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-400x174.png 400w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-600x262.png 600w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-768x335.png 768w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-800x349.png 800w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis-1024x447.png 1024w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig2-efficiency-duty-analysis.png 1087w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2 class=\"kme-h2\" dir=\"ltr\">3. Why the Weight Figure Is Misleading<\/h2>\n<p class=\"kme-paragraph\" dir=\"ltr\">The 1.4 kg weight of the PA2 made it look like a candidate, but weight similarity is meaningless once the power class differs. A 1.5 kg actuator that must output 240 W continuously has a <b><strong class=\"kme-text-bold\">power density of 160 W\/kg<\/strong><\/b> \u2014 servo-class territory. Achieving it requires every component to be re-architected around heat and efficiency: a brushless motor instead of a brushed one, rolling contact instead of sliding contact, and a thermally conductive aluminum housing instead of a sealed plastic one. The fact that both devices can weigh 1.5 kg tells you nothing about whether both can do the job; the internal engineering is fundamentally different.<\/p>\n<div id=\"attachment_3186\" style=\"width: 1034px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/%ec%a0%84%ea%b8%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3186\" class=\"size-full wp-image-3186\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2025\/09\/Default_AI_Title.png\" alt=\"\ud56d\uacf5\uc6b0\uc8fc \ubc0f \uc6b0\uc8fc \ubd84\uc57c\uc5d0\uc11c\uc758 \ud56d\uacf5\uae30 \uc120\ud615 \uc561\ucd94\uc5d0\uc774\ud130 \ubc0f \ud56d\uacf5\uae30 \uc804\uae30 \uc2e4\ub9b0\ub354 \uc801\uc6a9 \uc0ac\ub840\" width=\"1024\" height=\"1024\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2025\/09\/Default_AI_Title-150x150.png 150w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2025\/09\/Default_AI_Title-300x300.png 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2025\/09\/Default_AI_Title.png 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><p id=\"caption-attachment-3186\" class=\"wp-caption-text\">\ud56d\uacf5\uc6b0\uc8fc \ubc0f \uc6b0\uc8fc \ubd84\uc57c\uc5d0\uc11c\uc758 \ud56d\uacf5\uae30 \uc120\ud615 \uc561\ucd94\uc5d0\uc774\ud130 \ubc0f \ud56d\uacf5\uae30 \uc804\uae30 \uc2e4\ub9b0\ub354 \uc801\uc6a9 \uc0ac\ub840<\/p><\/div>\n<h2 class=\"kme-h2\" dir=\"ltr\">4. The Solution: A Servo Motor Linear Actuator (Electric Cylinder)<\/h2>\n<p class=\"kme-paragraph\" dir=\"ltr\">The requirement set \u2014 1600 N, 150 mm\/s, 100% duty, 1.5 kg \u2014 is a textbook specification for a <b><strong class=\"kme-text-bold\">servo motor linear actuator<\/strong><\/b> built as a ball-screw <b><strong class=\"kme-text-bold\">\uc804\uae30 \uc2e4\ub9b0\ub354<\/strong><\/b>. Figure 3 shows the proposed architecture.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/%ec%a0%84%ea%b8%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/\"><img decoding=\"async\" class=\"aligncenter size-fusion-800 wp-image-3877\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-800x359.png\" alt=\"\" width=\"800\" height=\"359\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-18x8.png 18w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-200x90.png 200w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-300x135.png 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-400x180.png 400w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-600x270.png 600w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-768x345.png 768w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-800x359.png 800w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution-1024x460.png 1024w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/fig3-electric-cylinder-solution.png 1082w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">4.1 Recommended configuration<\/h3>\n<table class=\"kme-table\">\n<colgroup>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"kme-table-row\">\n<th class=\"kme-table-cell kme-table-cell-header\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Item<\/p>\n<\/th>\n<th class=\"kme-table-cell kme-table-cell-header\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Proposed Specification<\/p>\n<\/th>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Actuator type<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Ball-screw electric cylinder (rod-style electromechanical linear actuator)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ubaa8\ud130<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">200\u2013400 W brushless servo motor, 3000 rpm rated, with encoder feedback<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Screw<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Ground ball screw, \u00d812\u201316 mm, 5 mm lead (\u03b7 \u2248 90%)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Drive<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Servo drive on a 24\u201348 V DC bus, with integrated position\/force control<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">Thrust \/ speed<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">1600 N continuous at 150 mm\/s, verified at the screw working point<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ub4c0\ud2f0 \uc0ac\uc774\ud074<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">100% (S1 continuous rating)<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ub1cc\uc878\uc911<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">100 mm, anti-rotation guided rod<\/p>\n<\/td>\n<\/tr>\n<tr class=\"kme-table-row\">\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\ubb34\uac8c<\/p>\n<\/td>\n<td class=\"kme-table-cell\">\n<p class=\"kme-paragraph\" dir=\"ltr\">\u2248 1.5 kg with aluminum housing<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"kme-h3\" dir=\"ltr\">4.2 Why this architecture meets every parameter<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">Efficiency closes the power gap.<\/strong><\/b> A ball screw&#8217;s rolling contact operates at ~90% efficiency. The same 240 W mechanical output now requires only ~267 W of motor output \u2014 well inside a 300 W servo motor&#8217;s continuous rating \u2014 drawing roughly <b><strong class=\"kme-text-bold\">11 A at 24 V instead of 67\u2013100 A at 12 V<\/strong><\/b>. The power budget goes from impossible to comfortable.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">Speed is no longer coupled to survival.<\/strong><\/b> A 3000 rpm servo motor driving a 5 mm-lead screw directly (150 mm\/s requires just 1800 rpm at the screw) operates in the middle of its rated speed range, not at its thermal edge. If more thrust margin is desired, a small precision planetary stage can be added without sacrificing the duty rating.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">Duty cycle becomes a non-issue.<\/strong><\/b> Brushless servo motors are rated for continuous (S1) operation by definition; there are no brushes to wear and copper losses are removed through the aluminum housing. The ball screw&#8217;s rolling contact generates minimal heat at the nut. A properly sized servo motor linear actuator is rated for <b><strong class=\"kme-text-bold\">100% duty at full rated force and speed simultaneously<\/strong><\/b> \u2014 the customer&#8217;s 80\u2013100% requirement becomes the design point rather than the failure point.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\"><b><strong class=\"kme-text-bold\">Life scales by orders of magnitude.<\/strong><\/b> Ball-screw life follows the standard L10 = (C\/F)\u00b3 relationship and is rated in millions of revolutions. At the customer&#8217;s cycle rate, the proposed cylinder delivers a service life measured in years of continuous shifts instead of days \u2014 with the added benefit of encoder feedback for closed-loop position control, soft starts, and programmable force limits that protect the customer&#8217;s tooling.<\/p>\n<h3 class=\"kme-h3\" dir=\"ltr\">4.3 A note on the premium alternative<\/h3>\n<p class=\"kme-paragraph\" dir=\"ltr\">For completeness: if the customer later demands higher dynamics (accelerations above ~1 g or cycle rates beyond what any screw can sustain), a direct-drive <b><strong class=\"kme-text-bold\">\uc120\ud615 \uc11c\ubcf4 \ubaa8\ud130<\/strong><\/b> \u2014 a tubular or flat linear motor with no screw at all \u2014 removes the last mechanical transmission element and offers essentially unlimited duty with micron-level repeatability. For the present 1600 N \/ 150 mm\/s duty point, however, the ball-screw electric cylinder is the more compact, more power-dense, and far more cost-effective choice; a linear servo motor would be over-specification.<\/p>\n<p dir=\"ltr\"><a href=\"https:\/\/jimiactuators.com\/ko\/%ec%a0%9c%ed%92%88\/%ec%84%a0%ed%98%95-%ec%95%a1%ec%b6%94%ec%97%90%ec%9d%b4%ed%84%b0-%eb%aa%a8%ed%84%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/%ec%a0%84%ea%b8%b0-%ec%8b%a4%eb%a6%b0%eb%8d%94\/\"><img decoding=\"async\" class=\"aligncenter size-fusion-800 wp-image-3878\" src=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-800x572.png\" alt=\"\" width=\"800\" height=\"572\" srcset=\"https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-18x12.png 18w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-200x143.png 200w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-300x214.png 300w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-400x286.png 400w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-600x429.png 600w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-768x549.png 768w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57-800x572.png 800w, https:\/\/jimiactuators.com\/wp-content\/uploads\/2026\/11\/b68f014fe87a0422361da7d652cf6b57.png 1004w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2 class=\"kme-h2\" dir=\"ltr\">5. Conclusion<\/h2>\n<p class=\"kme-paragraph\" dir=\"ltr\">The PA2 series remains an excellent <b><strong class=\"kme-text-bold\">12v actuator linear<\/strong><\/b> product for what it was designed to do: intermittent positioning of moderate loads at modest speeds \u2014 furniture, hatches, ventilation, light automation. But thrust, stroke, and weight matching a datasheet is not the same as matching an application. The moment the requirement includes <b><strong class=\"kme-text-bold\">150 mm\/s at 1600 N and 80\u2013100% duty<\/strong><\/b>, the governing constraints become power density, screw efficiency, and thermal design \u2014 and on all three, a brushed DC lead-screw actuator is disqualified by physics, not by preference.<\/p>\n<p class=\"kme-paragraph\" dir=\"ltr\">The correct engineering answer is a <b><strong class=\"kme-text-bold\">servo motor linear actuator<\/strong><\/b> in ball-screw electric-cylinder form: same 1.5 kg envelope, 90% drivetrain efficiency, 100% duty rating, closed-loop control, and a service life measured in years. If your application has outgrown a conventional <b><strong class=\"kme-text-bold\">electromechanical linear actuator<\/strong><\/b> on speed or duty cycle, contact our engineering team with your force\u2013speed\u2013duty working point \u2014 we will size a ball-screw <b><strong class=\"kme-text-bold\">\uc804\uae30 \uc2e4\ub9b0\ub354<\/strong><\/b> (or a linear servo motor where justified) against your actual cycle profile and provide the life and thermal calculations to prove it.<\/p>\n<h3 dir=\"auto\"><a href=\"https:\/\/www.facebook.com\/profile.php?id=100063752732208\" target=\"_blank\" rel=\"noopener\">\uc800\ud76c \ud398\uc774\uc2a4\ubd81 \ud398\uc774\uc9c0;<\/a>\u00a0<a href=\"https:\/\/www.youtube.com\/@solartrackers\" target=\"_blank\" rel=\"noopener\">\uc800\ud76c \uc720\ud29c\ube0c \ucc44\ub110;<\/a>\u00a0<a href=\"https:\/\/www.linkedin.com\/showcase\/solar-trackers-and-components\/about\/?viewAsMember=true\" target=\"_blank\" rel=\"noopener\">\uc800\ud76c \ub9c1\ud06c\ub4dc\uc778 \ud398\uc774\uc9c0;<\/a><\/h3>","protected":false},"excerpt":{"rendered":"<p>Case Study: Why a Standard 12V Actuator Linear Solution Failed [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3878,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[182,170],"tags":[],"class_list":["post-3874","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aerospace-defense-application","category-electric-cylinder-applications"],"_links":{"self":[{"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/posts\/3874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/comments?post=3874"}],"version-history":[{"count":3,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/posts\/3874\/revisions"}],"predecessor-version":[{"id":3881,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/posts\/3874\/revisions\/3881"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/media\/3878"}],"wp:attachment":[{"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/media?parent=3874"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/categories?post=3874"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jimiactuators.com\/ko\/wp-json\/wp\/v2\/tags?post=3874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}